Skip to main content

Coast Essential Construction

Rethinking the Building Envelope: Advanced Insulation and Sealing Techniques for Achieving Net Zero Ready

The building industry has faced increased pressure over the past decade to reduce its environmental footprint. One of the most effective ways to achieve this is by designing a home that is not just incredibly energy-efficient, but net zero ready.

Net zero ready homes are built to a level of energy efficiency such that, with the addition of a renewable energy source, they can produce as much energy as they consume over a year. Rooftop solar energy generation paired with a smaller, electric-powered heating/cooling system such as an air source heat pump, can make your home virtually self-sufficient.

Your home’s building envelope plays a crucial role in achieving Step 5 of the BC Energy Step Code, to qualify as net zero ready. In this article, we will explore how advanced insulation, the elimination of thermal bridging and meticulous sealing techniques form the backbone of a high-performance building envelope.

Understanding the building envelope

The building envelope of your home is the physical barrier between its interior and the great outdoors. It encompasses walls, roofs, floors, windows, and doors. That envelope serves as the primary defence against external weather conditions, and it helps regulate the temperature indoors by protecting against moisture, air leakage and outdoor noise.

A building envelope designed to the energy-efficient standards of net zero ready will provide minimal energy loss. Reducing the amount of energy required for heating, cooling, and ventilation will not only save your family a considerable amount on monthly energy bills but will lower consumption to the point where it can be offset by a renewable energy source like solar panels.

The importance of advanced insulation

Continuous insulation is a key component of the building envelope. Superior insulation will reduce heat transfer through walls, the roof, and floors, to keep the indoor environment comfortable regardless of outside temperatures. Conventional insulation solutions may not be sufficient to meet the rigorous standards for a net zero ready home. Advanced insulation techniques are essential to maximizing energy efficiency while minimizing thermal bridging, where heat escapes through gaps in the insulation.

Types of advanced insulation materials

Modern net zero homes have about double the insulation that goes into a conventional code-built house, and four to five times that used in a home from the 1950s. If the insulation doubles, energy loss is cut in half.

Mineral wool insulation: Mineral wool provides superior thermal insulation properties, with a higher R-value per inch compared to fibreglass, typically R4 to R4.3. Mineral wool’s dense fibre structure resists air movement, and it won’t shrink or settle, so it maintains its insulating performance over time. Joints stay closed, which minimizes thermal bridging, for stable continuous insulation.

Mineral wool is hydrophobic; it repels water rather than absorbing it. This can prevent loss of R-value, and it also inhibits mould/mildew growth if the insulation does get wet. Mineral wool is non-combustible and able to withstand temperatures up to 1000°C. The dense structure of mineral wool also provides superior acoustic performance, reducing noise transmission.

Blown-in or expanded foam insulation:: Blown-in insulation can be chopped up fibre, fibreglass or cellulose. It can be used to fill irregular spaces, gaps, and hard-to-reach areas in attics and wall cavities. It’s an excellent material for thorough coverage, helping to eliminate thermal bridging through framing members.

Loose-fill fibreglass provides about R-2.5 per inch of thickness, and cellulose offers a slightly higher R-value. Blow-in cellulose insulation has a high R-value in a relatively thin space. With multiple inches, blown-in cellulose can achieve very high total R-values. At a depth of two feet or more in attics, it can achieve R80. It also performs well with double-stud walls or other advanced framing techniques to allow for very thick insulation layers.

Expanded polystyrene (EPS), extruded polystyrene (XPS), and polyurethane foam (PUR) are commonly used in structural insulated panels (SIPS), typically sandwiched between two oriented strand boards (OSB) structural facings. SIPs are manufactured under factory-controlled conditions and can be built to fit almost any building design.

Rigid foam insulation: Rigid foam insulation provides exceptional insulation properties, typically ranging from R4 to R8 per inch. Rigid foam is often applied continuously on the exterior to eliminate thermal bridging through framing members. Applying continuous rigid foam over everything except the windows and doors helps maintain a very stable indoor temperature, preventing heat transfer.

Rigid foam resists moisture absorption and prevents mould growth and rot. When properly taped at the seams, rigid foam can serve as a drainage plane; in some cases replacing the need for housewrap. When sealed properly, it also creates an effective air barrier, reducing air leakage and drafts, while improving the energy efficiency and indoor air quality of the home.

Insulated concrete forms (ICFs): ICFs offer several key advantages that make them ideal for achieving high R-value, and continuous insulation in net zero homes. R-values are typically between R20 and R28 for the entire wall assembly, which is significantly higher than homes built with traditional wood framing.

By offering a continuous layer of insulation on both sides of the concrete core, you eliminate thermal bridging, and the thermal mass of that core helps stabilize indoor temperatures. ICF homes require 32% less energy to cool and 44% less energy to heat when compared with conventional construction. Properly installed, ICFs are airtight. They are highly resistant to water and moisture damage, and offer excellent fire resistance, with up to 4-hour fire ratings.

Vacuum insulation panels (VIPs): VIPs provide exceptional insulation properties, due to their extremely low thermal conductivity, typically around 0.004-0.006 W/mK. Superior R-value per inch – 5-10 times better than traditional insulation materials – typically R40 per inch or more, means walls and roofs can be much thinner while still achieving high insulation levels.

VIPs are popular in areas where maximizing insulation in thin spaces is crucial, such as balconies or door thresholds. High-quality VIPs will usually last 30-50 years before significant performance degradation.

Eliminating thermal bridging

Significant heat can be lost through 2x6s or steel beams, concrete, and window and door frames. Whether through materials or voids in our continuous insulation, we call this thermal bridging.

Wall studs: The standard code approach is to create a 2×6 wall rated at R20, but because the studs are pathways that can transfer heat from the drywall to the exterior, thermal bridging tends to reduce the performance to about R15. Building a double 2×4 wall, where the studs are staggered, with an additional 25% insulation from the thicker wall, this high-performance design combats thermal bridging and can deliver about R40 energy performance.

Window and doorframes: The frames of windows and doors are typically less insulated than the surrounding walls. This can potentially lead to thermal bridging. Using high-performance windows and doors with thermally broken frames made of low-conductivity materials like wood, fibreglass, or insulated PVC, instead of aluminum, is the best way to eliminate thermal bridging. Positioning frames in line with the wall’s thermal control layer/insulation is another way to prevent thermal bridging.

Roof and wall junctions: If not properly insulated, the connection between the roof and walls is another common area where thermal bridging can occur. Using continuous exterior insulation that extends from the walls up and over the roof edge will create an unbroken thermal barrier at the junction. Installing a structural thermal break material like Compacfoam at the roof-wall connection can isolate the conductive framing elements. Structural insulated panels (SIPs) are also a way to reduce thermal bridging in the wall and roof framing.

Balconies and cantilevers: Structural elements that extend outside the thermal envelope, such as balconies or cantilevered sections, are a common source of thermal bridging. Instead of extending the interior floor slab, designing balconies as bolt-on structures that attach to the building exterior helps avoid penetrating the building envelope. For steel balconies, reducing the number of connection points to the building minimizes thermal bridging pathways.

Foundation and floor slabs: The junctions between the foundation and the walls, and floor slabs and walls, are areas where thermal bridging often occurs. Systems like insulated concrete forms (ICFs) or insulated foundation systems that wrap the entire foundation in a continuous layer are two solutions to thermal bridging. Another is placing a continuous horizontal layer of rigid foam insulation (like XPS or EPS) or mineral wool under the entire concrete slab.

The role of airtightness in energy efficiency

Advanced sealing techniques like the installation of high-performance windows and doors, with advanced weatherstripping and insulated frames, should be considered essential for eliminating air leakage. Designing a continuous air barrier system involves creating an unbroken layer of materials that prevents air from entering or exiting the building envelope. Membranes, tapes and sealants are applied to the exterior sheathing, around windows and doors, and at all joints and seams.

On the inside, the airtight drywall approach (ADA) involves sealing all penetrations in the drywall with caulking or foam sealants. The detailing includes electrical outlets, light fixtures, and plumbing pipes and reduces air leakage through walls and ceilings. The ductwork in many homes can also be a significant source of air leakage. Sealing ducts with mastic or foil tape can prevent heated or cooled air from escaping.

The blower door test is a standard diagnostic tool used to measure the airtightness of a home. The house is depressurized with a powerful fan, helping the technician identify leaks and weak points in the building envelope. Problem areas can then be sealed to reduce air infiltration.

The takeaway

Achieving net zero ready status requires a comprehensive approach to building envelope design, that focuses on advanced insulation, and the elimination of thermal bridging and sealing techniques. By selecting superior insulation materials, employing airtight construction methods and meticulous detailing, in a holistic design strategy, your home will not only be energy-efficient but also comfortable, durable, and environmentally responsible.

This website uses cookies to ensure you get the best experience from your visit.

Before After
Before After
Before After